| Measuring rangeillumination | 10 ÷ 200,000 lux |
| The limits of the permissible basic relative error of measurements of illumination in the visible region of the spectrum | ± 8,0 % |
| The limits of the additional relative error of the device when measuring optical quantities, due to a change in the sensitivity of the photometric head when the air temperature in the measuring area changes for every 10 ° C in the range from -30 to +15 and from +25 to +60 °C | ± 3,0 % |
| Measuring rangeair temperature | -30 ÷ +60 °With |
| The limits of the permissible absolute error of measuring air temperature, in the ranges: from -30 to -10, inclusive. ranges from -10 to +15 degrees. ranges from +15 to +25°Inclusive. ranges from +25 to +45°Inclusive. range from +45 to +60 |
0.5With 0.3 With ± 0.2°With ± 0.3°With ± 0.5 °S |
| Measuring rangerelative humidity | 5 ÷ 98 % |
| The limits of the permissible basic absolute error of relative humidity measurements in the air temperature range from +15 to +25 °C | 3.0% rel. |
| The limits of the permissible additional absolute error of relative humidity measurements with temperature changes for every 10 °C in the ranges from +10 to +15 °C and from +25 to +60 °C, % | ± 3,0 % |
| Measuring rangeair velocity | 0.1 ÷ 20 m/s |
| The limits of the permissible basic absolute error of measuring air velocity (V) in the range from +15 to +25 °C: | |
| in the range (0.1 ÷ 1.0) m/s | (0.045 + 0.05)m/s |
| in the range (1.0divide 20) m/s | (0.1 + 0.05)m/s |
The combined device "TKA-PKM" (63) has the option of measuring the average air velocity over a certain period of time (100 s) (in accordance with the recommendations of the SanPiN, see, for example, the Manual "Physical Factors. Ecological and hygienic assessment and control. M. "Medicine", 1999, vol. 2, p. 416).
| Signal processing unit | 160 x 86 x 31 mm |
| Measuring head | 425 x 48 x 55 mm |
| Weight of the device (max.) | 0.45 kg |
| A NiMH rechargeable battery is used to power the devices. The battery size is "Crown" | 8.4 V |